I believe in the converter operates such that. Is this correct?
below resonance, vc(t) leads ig(t)
above resonance, vc(t) lags ig(t)
Thanks
Subscribe to:
Post Comments (Atom)
Blog for students taking ECEN5817 Resonant and Soft Switching Techniques in Power Electronics, ECEE Department, University of Colorado at Boulder, Spring 2012
1 comment:
Correct!
Below resonance the tank is inductive, & above capacitive.
Post a Comment